For years, the story of the Phoenix office market was simple: tenants fled older buildings for new Class A space, and everything else sat empty. The second quarter of 2026 complicated that story. According to Cushman & Wakefield, metro Phoenix office vacancy fell 70 basis points in a single quarter to 25.4 percent, the fastest decline in more than a decade. Class B buildings led the recovery, with vacancy at 25.7 percent, down 380 basis points from its peak in the third quarter of 2024. CBRE reported that Class B properties accounted for about 398,000 of the nearly 490,000 square feet of net absorption it tracked during the quarter.
Brokerages measure the market differently, so their headline vacancy rates vary. CBRE put overall vacancy at 19.1 percent, and others reported figures in between. But the direction is consistent: demand has turned positive, and well-located, well-run Class B buildings are winning tenants who want quality without top-tier rents.
That creates an opening for owners of 1980s through early 2000s office stock across the Valley. The buildings that keep this momentum will be the ones that close the performance gap with newer properties. Smart building retrofits are one of the most cost-effective ways to do it.
What Tenants Actually Ask About
Leasing teams in Scottsdale, Tempe and the Camelback corridor hear the same questions again and again from prospective tenants. Most of them map directly to building data:
- "Will my people be comfortable in July?" Temperature complaints in older buildings usually trace to poorly balanced air distribution, failing rooftop units and west-facing zones that overheat every afternoon.
- "Is the air healthy?" Carbon dioxide levels, filtration and ventilation rates have become standard due-diligence questions since the pandemic.
- "How much space do we really need?" Hybrid work has made tenants skeptical of their own headcount assumptions. They want utilization data.
- "What will operating expenses look like?" Arizona's rising electricity demand and utility rate cases make energy costs a larger part of the conversation.
- "Is the building secure?" Access control and visitor management expectations have risen, especially for tenants in healthcare, finance and technology.
An owner who can answer those questions with measured data, rather than assurances, has a real advantage in a competitive leasing market.
Where Retrofits Deliver the Most for Older Valley Buildings
| Retrofit | What It Solves | Typical Approach | Relative Cost |
|---|---|---|---|
| Wireless zone temperature and humidity sensors | Comfort complaints, hot west-side zones, poor thermostat placement | Battery-powered sensors reporting to a gateway; no new wiring | Low |
| HVAC fault detection and diagnostics | Failing economizers, stuck dampers, simultaneous heating and cooling, compressor short cycling | Analytics software connected to existing controls or retrofit controllers on rooftop units | Low to medium |
| Indoor air quality monitoring | Tenant health questions, ventilation verification | CO2, particulate and VOC sensors in representative spaces, with a tenant-facing dashboard | Low |
| Occupancy and utilization sensing | Space planning, cleaning schedules, HVAC scheduling | Privacy-preserving people counters or desk sensors | Low to medium |
| Electrical submetering | Tenant energy allocation, peak demand management | Current transformer meters on panels and major loads | Medium |
| Cloud access control | Security, visitor management, mobile credentials | Replace legacy card systems with networked readers | Medium |
Wireless technology is what makes these projects practical in older buildings. Running new cable through occupied floors with asbestos-era ceilings or limited plenum access can be expensive and disruptive. Battery-powered sensors and long-range wireless gateways avoid most of that work.
Heat Is the Differentiator in Arizona
Every market cares about comfort and energy costs. In Phoenix, heat magnifies both. Older buildings often have single-pane or early double-pane glass, aging rooftop units operating near the end of their design life, and control sequences that were never tuned for the extended 110 degree stretches that have become routine.
Fault detection pays off particularly well here. A rooftop unit with a failed economizer or a refrigerant problem might limp through spring unnoticed, then fail during the first heat wave, leaving a tenant floor at 85 degrees. Analytics that catch those faults in April let the owner fix them before tenants notice. That directly affects renewal decisions, which often hinge on how a building performed during the previous summer.
A Phased Plan for a Typical 100,000 Square Foot Class B Building
- Start with a baseline. Install wireless temperature and CO2 sensors across representative zones and connect analytics to existing HVAC controls. Run for 60 to 90 days to see how the building actually performs.
- Fix the obvious problems. Most buildings reveal a short list of faulty equipment, poor schedules and overheating zones. Correcting them usually costs little and produces immediate comfort and energy improvements.
- Add occupancy data. Use utilization information to align HVAC schedules with actual use and to support tenant space planning conversations.
- Make it visible. Share air quality and comfort data with tenants and prospects through a simple dashboard or lobby display. Transparency builds trust.
- Tackle bigger capital items with evidence. Use a year of data to prioritize equipment replacement, choosing units based on actual performance rather than age alone.
A Tale of Two Buildings
Consider two similar 1990s office buildings on the same Tempe street, each about 100,000 square feet with aging rooftop units and a mix of small and mid-sized tenants.
The first owner waits. In June, two rooftop units fail during a heat wave. A law firm on the third floor works through a week at 84 degrees while replacement parts are ordered. The firm's managing partner mentions the experience during renewal talks the following spring and eventually relocates to a newer building in Scottsdale.
The second owner installs wireless zone sensors and HVAC analytics in February. The system flags a failed economizer, two units with signs of low refrigerant and a west-facing zone that overheats every afternoon because a damper is stuck. Repairs cost a few thousand dollars and are completed in April. When the heat arrives, complaints stay low. The owner shares summer comfort and air quality data with a prospective tenant touring the building in September, and the prospect signs.
The details are illustrative, but property managers across the Valley will recognize the pattern. Summer performance drives renewal conversations, and data turns maintenance from reactive to planned.
Integrating With What the Building Already Has
Many older Valley buildings have a building automation system installed decades ago, sometimes with proprietary controllers and limited documentation. Replacing it outright is expensive. A better first step is usually an overlay: analytics software and wireless sensors that read data from existing controls where possible, supplemented by retrofit controllers on rooftop units that lack them. Insist on open protocols such as BACnet so future upgrades are not locked to a single vendor, and make sure the owner, not the integrator, holds administrative access and documentation.
Cybersecurity Cannot Be an Afterthought
Every connected sensor, controller and gateway expands the building's attack surface. Summer 2026 brought a wave of attacks on internet-exposed industrial controllers at U.S. water utilities, a reminder that operational technology connected carelessly will eventually be found.
Owners should require vendors to use encrypted connections, unique credentials and a patching commitment. Building systems should sit on a network separate from tenant IT, and remote access for contractors should go through a single controlled path with multifactor authentication. Tenants in regulated industries increasingly ask about these controls during lease negotiations.
Protecting Occupant Privacy
Occupancy sensing raises understandable concerns. Choose technologies that count people without identifying them, such as thermal or time-of-flight sensors rather than cameras, and be transparent with tenants about what is collected and why. Aggregate data by floor or zone rather than tracking individuals. Clear policies make tenants more comfortable and avoid disputes later.
For multi-tenant buildings, publish a short privacy notice in the lobby or tenant portal, and give tenants access to data about their own suites. Openness about what the building measures tends to turn a potential concern into a selling point.
Measuring the Return
Energy savings are the easiest benefit to quantify, but in the current Phoenix market they may not be the largest. Consider leasing velocity, tenant retention and operating cost per square foot alongside energy. A building that renews one more mid-sized tenant because summer comfort complaints disappeared can recover a retrofit's cost many times over in avoided downtime, tenant improvement allowances and leasing commissions.
Track comfort complaints, work orders and after-hours service calls before and after the retrofit. These operational metrics tell property managers and owners whether the investment is working long before annual energy bills arrive.
What's Ahead for Valley Office Buildings
Several forces are shaping the next few years. Newmark has noted that part of the recent vacancy improvement comes from obsolete buildings being removed from inventory and repositioned for other uses, which rewards owners who invest in the buildings that remain. Limited new construction means well-maintained existing stock will carry more of the market's demand. And utility costs in Arizona are likely to keep rising as the grid absorbs data center growth.
Class B owners in Scottsdale, Tempe and Phoenix have a window to turn a cyclical recovery into a lasting competitive position. Measured comfort, healthy air and predictable operating costs are what tenants remember when their leases come up for renewal. Owners looking for local building automation and smart building integrators can browse the IoT Arizona company directory.
Related articles
Smart Buildings
Smart Buildings
IoT Water Leak Detection in Arizona: Protecting Homes, Apartments and Commercial Properties
Smart Buildings
IoT HVAC Monitoring in Arizona: What to Measure in the A2L Refrigerant Era
Smart Buildings