Energy & Sustainability
Arizona's Grid Broke Two Records in One Day: What Businesses Should Measure Before Next Summer
Published by IOT Arizona Research & Editorial Team

- The Numbers Behind Summer 2026
- Demand Charges: The Line Item to Attack First
- Five Loads to Instrument First
- Pre-Cooling: The Desert's Cheapest Battery
- Solar and Batteries: Monitoring Decides the Payback
- A Procurement Checklist That Saves Headaches
- Objections Facility Teams Raise, and Honest Answers
- What to Watch Before Summer 2027
On a Friday in late July 2026, with Phoenix at 117 degrees, Arizona's two largest utilities each broke their all-time demand records within hours of each other. APS delivered more than 9,063 megawatts. SRP reported a peak of 9,072 megawatts. Both landed at roughly 90 percent of the summer capacity they had projected to state regulators in April, and both had to lean on the regional grid to keep the lights on.
For Arizona business owners and facility managers, those headlines translate into a direct question: how much of your own summer bill is set by a handful of hot afternoons, and how much control do you actually have over it? The honest answer for most commercial buildings is "a lot more than you think," provided you can see what your equipment is doing in close to real time.
This guide focuses on behind-the-meter energy IoT: the sensors, submeters and controls that sit on your side of the utility meter. It skips the sustainability slogans and concentrates on what to measure first, how to estimate value and how to avoid the procurement mistakes that turn good intentions into dashboards nobody uses.
The Numbers Behind Summer 2026
Three trends are converging on the Arizona grid at once.
- Heat-driven peaks keep climbing. This year's records came in 400 to 500 megawatts above the previous highs, enough to serve somewhere between 65,000 and 110,000 homes.
- Data centers now shape peak growth. APS reported that data centers drew up to 630 megawatts during its record day, close to 7 percent of total demand and about 200 megawatts more than during its 2025 peak. That means data centers accounted for roughly half of APS's year-over-year peak growth.
- The policy backdrop is shifting. In July 2026, the Arizona Corporation Commission repealed the state's energy efficiency standards, which had been in place for about 15 years, following an earlier move away from the renewable energy standard.
The last point deserves attention. Utility efficiency programs have historically been one of the main sources of rebates for commercial lighting, HVAC and controls projects. Existing programs may continue for some time, and utilities may still choose to offer incentives for their own planning reasons, but businesses should not assume the same level of support will be available in future years. Check what is currently offered before planning around it. The practical effect is that projects which pay for themselves on operating savings alone, without rebates, become the safest bets. Measurement-first IoT projects tend to fall into that category.
Demand Charges: The Line Item to Attack First
Many commercial electric rates in Arizona include a demand charge, a fee based on the highest rate of power draw recorded during a billing period, often measured over short intervals within on-peak hours. A building can use modest energy all month and still pay a large demand charge because every rooftop unit, compressor and pump happened to run at full load during the same 15 minutes on one August afternoon.
That structure is why demand is where IoT tends to pay off first. Energy consumption is spread across thousands of hours. Peak demand is set in a few specific moments, and those moments can be managed if you can see them coming.
An illustrative example
Consider a 60,000 square foot office building in Tempe with eight rooftop units. Without coordination, compressors on all eight units often cycle on together during the hottest part of the afternoon. By adding space temperature sensors and a supervisory controller that staggers compressor starts and allows slight setpoint drift during the on-peak window, the building trims its monthly peak by 80 kilowatts. At an assumed demand rate of $15 per kilowatt, that is about $1,200 per month during summer billing periods. Your actual rate, billing structure and savings will differ, so run the calculation with your own bills, but the logic holds for most multi-unit commercial sites.
Five Loads to Instrument First
Not every circuit deserves a sensor. In Arizona commercial and light industrial buildings, the following loads usually account for most controllable peak demand.
| Load | Why It Matters in Arizona | What to Monitor | Typical Control Strategy |
|---|---|---|---|
| Rooftop units and chillers | Cooling dominates summer peaks in nearly every building type | Compressor run status, supply air temperature, space temperature, power draw | Staggered starts, pre-cooling, setpoint drift during on-peak hours |
| Refrigeration | Grocery, food service and cold storage run heavy loads in extreme heat | Case and box temperatures, compressor power, defrost cycles | Shifting defrost out of on-peak hours, condenser maintenance alerts |
| Air compressors and process loads | Leaks and idle running waste energy around the clock | Pressure, runtime, power draw | Leak detection, shutdown during idle periods, sequencing |
| EV chargers | Fleet and workplace charging can create new afternoon spikes | Per-port power and session timing | Managed charging that shifts or throttles sessions during peaks |
| Pumps | Irrigation, cooling towers and pools run long hours in summer | Runtime, flow, power draw | Variable speed operation and scheduling outside on-peak windows |
Pre-Cooling: The Desert's Cheapest Battery
A building's own mass can store cooling. By bringing space temperatures down a few degrees in the late morning, before the on-peak window begins, a building can coast through part of the afternoon with fewer compressors running. The concept is decades old. What IoT adds is the confidence to do it without comfort complaints: wireless space sensors show exactly how quickly each zone warms, so the strategy can be tuned zone by zone rather than guessed at.
Pre-cooling works best in buildings with heavier construction, such as concrete tilt-up warehouses and older masonry offices common across Phoenix and Mesa. Lightweight buildings with large west-facing glass walls hold cooling for less time and need a more cautious approach.
Solar and Batteries: Monitoring Decides the Payback
Arizona businesses installing rooftop solar and on-site batteries often discover that the hardware is only half of the value. A battery that discharges at the wrong time, or runs out of charge 30 minutes before the building's true peak, saves little on demand charges. Interval-level monitoring of building load, solar output and battery state of charge is what allows dispatch logic to target the right hours. Before approving a storage project, ask the installer to model savings using at least a full year of your 15-minute interval data, not a monthly bill summary.
A Procurement Checklist That Saves Headaches
- Get your interval data first. Download at least 12 months of interval usage from your utility account. It shows exactly when your peaks happen and is free.
- Require open protocols. Controllers and sensors should speak BACnet or Modbus and integrate with your existing building automation system rather than locking you into a single vendor.
- Own your data. The contract should guarantee raw data export at any time and after cancellation.
- Ask about cybersecurity. Anything that can switch equipment remotely is a potential entry point. Require unique credentials, encrypted connections and a patching commitment.
- Start with one building. Prove savings over a full summer before rolling out across a portfolio.
- Assign an owner. Every alert type needs a named person who responds. Unanswered alerts are the most common reason energy dashboards fail.
Objections Facility Teams Raise, and Honest Answers
"Our building automation system already does this." Many Arizona buildings have a BAS, but it was often programmed years ago for comfort, not demand. It may control equipment without recording power draw, and it rarely knows when the utility's on-peak window starts. Adding submetering and demand-aware logic to an existing BAS is usually cheaper than replacing it.
"Tenants will complain." Some will, if setpoints drift without warning. Programs that limit drift to one or two degrees, avoid occupied conference rooms and communicate the reason tend to see few complaints. Space sensors also help settle disputes, since you can show what the temperature actually was.
"We cannot justify the cost without a rebate." Start small. Monitoring a few large loads for one summer costs far less than a full retrofit and produces the interval data needed to build a real business case, with or without incentives.
"Our equipment is too old." Older rooftop units are often the best candidates, because they lack built-in intelligence. Retrofit controllers and current sensors clamp onto existing wiring and can add visibility to equipment that still has years of service left.
What to Watch Before Summer 2027
Several developments could change the economics for Arizona businesses over the next year. Demand response programs, which pay customers to reduce load during grid emergencies, have been used by SRP for both residential and commercial customers and are likely to grow in importance as reserve margins tighten. Large-load growth from data centers remains the subject of active proceedings at the Arizona Corporation Commission, which held a workshop on large-load and data center customers in April 2026. And rate cases at the major utilities will continue to reshape how demand and time-of-use charges are structured.
The businesses best positioned for those changes will be the ones that already know their load profile in detail. A connected building can enroll in demand response, adapt to a new rate design or justify a battery project with evidence rather than estimates. For help finding integrators, the IoT Arizona company directory lists local energy management and building automation providers by city.
Related articles
Energy & Sustainability
Energy & Sustainability
How Arizona Solar Projects Are Becoming Connected Energy Systems
Energy & Sustainability
IoT Building Energy Management in Arizona: Running Efficiency as a Continuous Program, Not a Rebate Project
Energy & Sustainability